{"results":[{"id":"sb721-cited","title":"Apartment buildings cited for a missing SB 721 balcony inspection (Los Angeles)","short":"SB 721 balcony inspections: buildings already cited","what":"Apartment buildings the LA Housing Department wrote up for not having the state-required inspection of balconies, decks, stairs and walkways (exterior elevated elements).","place":"us-ca-los-angeles","law":{"name":"SB 721 (Health and Safety Code 17973)","url":"https://legiscan.com/CA/text/SB721/2017"},"who_must_comply":"Buildings with 3 or more apartments and wood-supported elements more than 6 feet above the ground","how_often":"First inspection due 1 January 2026, then every 6 years","who_may_sign":"A licensed architect, a licensed civil or structural engineer, an A, B or C-5 contractor with 5 years of multistory wood-frame work, or a certified building inspector","penalty":"Civil penalties of $100 to $500 a day after a 30-day corrective notice, and a lien on the property","who_buys_it":"Structural and civil engineers, architects and inspection firms that do SB 721 reports","fields":["APN","address","ZIP","units","date cited","citations","other lists at the same address"],"source":{"name":"LA Housing Department, Property Look-Up for Violations (data.lacity.org)","url":"https://data.lacity.org/d/cr8f-uc4j"},"notes":["A citation means the Housing Department found no inspection on file when it visited; the owner may have had one done since.","The Housing Department publishes this dataset on its own schedule; the window shows which inspections it covers."],"rows":1461,"refreshed_at":"2026-11-19 11:09:09","window":{"from":"2026-01-29","to":"2026-07-29"},"status":"ok","page":"https://sos.city/compliance/sb721-cited","report":"https://api.sos.city/v1/compliance/report?list=sb721-cited","items":"https://api.sos.city/v1/compliance/items?list=sb721-cited"},{"id":"ebewe-not-complied","title":"Buildings that did not comply with LA's energy and water benchmarking (EBEWE)","short":"EBEWE energy benchmarking: buildings not complied","what":"Buildings of 20,000 square feet or more that LADBS lists as not complied for the latest program year of the Existing Buildings Energy and Water Efficiency program.","place":"us-ca-los-angeles","law":{"name":"LA Municipal Code Chapter IX, Division 97 (EBEWE, Ordinance 184674)","url":"https://codelibrary.amlegal.com/codes/los_angeles/latest/lamc/0-0-0-293962"},"who_must_comply":"Privately owned buildings of 20,000+ sq ft, and city buildings of 7,500+ sq ft","how_often":"Benchmarking every year; an ASHRAE Level II energy and water audit and retro-commissioning every 5 years by the last digit of the building ID","who_may_sign":"Benchmarking: anyone, in ENERGY STAR Portfolio Manager. Audits and retro-commissioning: supervised by a California-licensed engineer or architect","penalty":"Non-compliance fees and public listing by LADBS","who_buys_it":"Energy auditors, retro-commissioning providers, benchmarking services and property-management firms","fields":["building ID","address","ZIP","size class","floor area","year built","main use","filing company (where it's a company)","program year"],"source":{"name":"LADBS, Existing Buildings Energy and Water Efficiency (EBEWE) Program (data.lacity.org)","url":"https://data.lacity.org/d/9yda-i4ya"},"notes":["The latest program year can still be closing, so some buildings listed as not complied file late; read the figure as a ceiling.","Where the filer is a person rather than a company, the name is left out."],"rows":5082,"refreshed_at":"2026-11-19 13:08:59","window":{"from":null,"to":null},"status":"ok","page":"https://sos.city/compliance/ebewe-not-complied","report":"https://api.sos.city/v1/compliance/report?list=ebewe-not-complied","items":"https://api.sos.city/v1/compliance/items?list=ebewe-not-complied"},{"id":"code-cases-open","title":"Open code-enforcement cases at LA buildings (LADBS)","short":"Open LADBS code-enforcement cases","what":"Every code-enforcement case LADBS lists as open: the owner has to correct the violation and pay the department's fees, and unpaid fees can become a lien.","place":"us-ca-los-angeles","law":{"name":"LA Municipal Code (LADBS code enforcement, fees and liens)","url":"https://dbs.lacity.gov"},"who_must_comply":"Owners of the property named in each case","how_often":"Until LADBS closes the case","who_may_sign":"Permit expediting needs no licence; plans need an architect or engineer; the work needs a licensed contractor","penalty":"Code-enforcement fees, non-compliance fees and possible liens","who_buys_it":"Permit expediters, architects, engineers, contractors and property-management firms","fields":["case number","address","ZIP","date opened","case type (LADBS's own code)","planning area","parcel id"],"source":{"name":"LADBS, Code Enforcement Case - Open (data.lacity.org)","url":"https://data.lacity.org/d/u82d-eh7z"},"notes":["Case types are LADBS's own codes (GENERAL, VEIP, BILLBOARDS, PACE, CNAP and others); ask LADBS what each covers before quoting it to an owner."],"rows":28718,"refreshed_at":"2026-11-19 08:08:41","window":{"from":"1995-02-03","to":"2026-11-14"},"status":"ok","page":"https://sos.city/compliance/code-cases-open","report":"https://api.sos.city/v1/compliance/report?list=code-cases-open","items":"https://api.sos.city/v1/compliance/items?list=code-cases-open"},{"id":"soft-story-open","title":"Soft-story retrofit orders not yet complied (LA)","short":"Soft-story retrofit orders still open","what":"Wood-frame buildings with a soft, weak or open-front ground floor that LADBS ordered retrofitted and that have no certificate of compliance yet.","place":"us-ca-los-angeles","law":{"name":"LA Ordinance 183893 (mandatory soft-story retrofit)","url":"https://dbs.lacity.gov"},"who_must_comply":"Pre-1978 wood-frame buildings with tuck-under parking or open ground floors that received an order","how_often":"One-time, in stages from the date of the order","who_may_sign":"A licensed engineer designs the retrofit; a licensed contractor builds it","penalty":"Fines, a substandard-building posting and, in the end, orders to vacate","who_buys_it":"Structural engineers, seismic retrofit contractors and lenders","fields":["address","ZIP","order date","permit","permit issued","work-complete deadline"],"source":{"name":"LADBS, Soft-Story Compliance (data.lacity.org)","url":"https://data.lacity.org/d/dqq4-799r"},"notes":["A building with a permit issued is under way; the deadline shown is LADBS's latest extended date where one is published."],"rows":1862,"refreshed_at":"2026-11-19 09:08:59","window":{"from":"2016-05-12","to":"2026-04-13"},"status":"ok","page":"https://sos.city/compliance/soft-story-open","report":"https://api.sos.city/v1/compliance/report?list=soft-story-open","items":"https://api.sos.city/v1/compliance/items?list=soft-story-open"},{"id":"ndc-concrete","title":"Non-ductile concrete buildings with the retrofit not complete (LA)","short":"Non-ductile concrete: evaluations and retrofits due","what":"Older concrete buildings LADBS ordered evaluated and retrofitted, where the retrofit is not yet complete.","place":"us-ca-los-angeles","law":{"name":"LA Municipal Code 91.9501 and following (non-ductile concrete buildings)","url":"https://dbs.lacity.gov"},"who_must_comply":"Concrete buildings permitted before January 1977 that received an order","how_often":"Checklist, then a structural evaluation, then a retrofit within 25 years of the order","who_may_sign":"A licensed structural or civil engineer","penalty":"LADBS orders and fines","who_buys_it":"Structural engineering firms","fields":["address","ZIP","order date","checklist filed","plans submitted","evaluation deadline","retrofit deadline"],"source":{"name":"LADBS, NDC Building Level (data.lacity.org)","url":"https://data.lacity.org/d/ke3z-xgni"},"notes":["Deadlines are LADBS's own dates, extended dates where it publishes one."],"rows":818,"refreshed_at":"2026-11-19 10:09:33","window":{"from":"2017-11-20","to":"2026-10-05"},"status":"ok","page":"https://sos.city/compliance/ndc-concrete","report":"https://api.sos.city/v1/compliance/report?list=ndc-concrete","items":"https://api.sos.city/v1/compliance/items?list=ndc-concrete"},{"id":"stormwater-facilities","title":"Industrial stormwater permit facilities in LA County, with Water Board actions","short":"Industrial stormwater (IGP) facilities and violations","what":"Industrial facilities in Los Angeles County covered by, or told to file for, California's Industrial General Permit, with the State Water Board's enforcement actions against each.","place":"us-ca-los-angeles-county","law":{"name":"California Industrial General Permit (Order 2014-0057-DWQ, as amended)","url":"https://www.waterboards.ca.gov/water_issues/programs/stormwater/industrial.html"},"who_must_comply":"Industrial facilities in the permit's Attachment A (warehousing, auto parts, scrap, metal finishing, trucking, manufacturing and more)","how_often":"Monthly visual checks, storm sampling, an annual report by 15 July; exceedance response reports when limits are exceeded","who_may_sign":"Exceedance response work needs a Qualified Industrial Stormwater Practitioner (QISP); Level 2 structural fixes need a licensed engineer","penalty":"Notices of violation, administrative civil liabilities and citizen suits under the Clean Water Act","who_buys_it":"Stormwater consultants (QISPs), environmental engineers, labs and compliance firms","fields":["WDID","permit status","facility name","operator (where it's a company)","address","city","ZIP","industry (SIC)","covered since","Water Board actions in the last 24 months","last action date and type"],"source":{"name":"State Water Board SMARTS, via data.ca.gov (facility information and enforcement actions)","url":"https://data.ca.gov/dataset/stormwater-regulatory-including-enforcement-actions-information-and-water-quality-results"},"notes":["Contact people, phones and emails in the state's filing are left out; the WDID opens the facility's public record in SMARTS."],"rows":5916,"refreshed_at":"2026-11-19 18:08:34","window":{"from":"1992-01-26","to":"2026-10-29"},"status":"ok","page":"https://sos.city/compliance/stormwater-facilities","report":"https://api.sos.city/v1/compliance/report?list=stormwater-facilities","items":"https://api.sos.city/v1/compliance/items?list=stormwater-facilities"}],"notice":"Public records index: show the publisher and link to the original. Not for tenant, employment, credit or insurance screening. Not an emergency service."}